   MH-32TK elevator IC card management system

manual

(V3.5)

   table of Contents

Chapter 1 System Composition and Function Introduction ... 3

1.1 System Composition ... 3

1.2 System composition list ... 3

1.3 Function List ... 3

Chapter 2 Controller Description ... 5

2.1 Controller parameters ... 5

2.2 Interface Description. 5

Chapter 3 Installation Instructions ... 8

3.1 Controller wiring diagram ... 8

3.2 System Installation and Fixation. 9

3.3 Connection between card issuer and computer ... 9

Chapter 4 Debugging and Running. 10

4.1 Preparations before powering on. 10

4.2 Checking after power on ... 10

4.3 Controller Configuration. 10

4.4 Running Tests. 11

Chapter 5 Frequently Asked Questions ... 13

Appendix 1 Detailed Explanation of Buzzer Beep ... 16

Appendix 2 Explanation of Indicator Lights. 17

Appendix III Elevator Number Setting Method ... 18

   Chapter 1 System Composition and Function Introduction

   1.1 System composition

Through the management of authorized IC cards, this system can realize the management and control of elevator users, elevator use rights, elevator running time, floor opening hours, etc., so that the property management department can easily manage elevator users and elevators MH-32T intelligent elevator IC card management system is a centralized integrated control platform with the following structure:

1), IC card management center (computer software) (initial login password is empty)

2), card issuer

3), MH-32TK controller

4), card reader

5) RF IC card

6), other auxiliary products, etc.

   1.2 System composition list

product name

Specifications

unit

Description

Management Center Software

V3.5

set

Installed in the computer, is the management platform for the entire system

Card writer

MH-RW-64

set

Achieve card issuance and management with IC card management center

Internal controller

MH-32TK

set

Installed in the car or car roof to control the elevator

Card reader

MH-012

set

Installed on the car floor panel or car wall, connected with the internal controller, collects the IC card information and transmits it to the controller

Management Card

Philips M1 S50

Zhang

Controller management card, one set of software and one set.

User RF IC Card

Philips M1 S50

Zhang

For users to use the elevator

   1.3 Feature List

Function item

Function Description

Control with ladder authority

Valid credit card can select the designated authorized floor

Selective Hierarchical Control

Each layer selection button can be controlled independently, controlling 64 layers

Double insurance structure

In the event of a failure, disable the elevator control function and resume use of the elevator

One card multiple ladder function

One user IC card can authorize the use of multiple elevators

Massive user information database

Support up to 60,000 elevator IC cards

Card loss function

When the user card is lost, the lost card can be reported, and the original lost card will be invalid automatically

Flexible ladder limit mode

Flexible configuration of the number of times the user uses the elevator card, the period of use, the available time period, the available date, etc.

Charge function

Hierarchical billing, time-of-day billing, and pay-per-view billing can be flexibly configured, with or without charge

User blacklist function

After the specified user is blocked, the elevator can no longer be used. It will not be used until it is opened again. It can store up to 10,000 blacklists.

Elevator operation management

You can set the disabled period and available date for each floor of the elevator independently. When the invalid period or date, the floor is disabled and the card is invalid

Output time setting

You can set the open retention time of buttons, etc. according to actual needs

Swipe record access

20,000 swipe card records are stored cyclically and can be read at any time. Power-down data can be maintained for 10 years

Fire function

When the elevator fires, it will automatically exit the IC card management after receiving the fire signal.

Data export function

Record export function via TF card

Switch enable / disable IC card management

Can manage card control whether to enable elevator IC card management

   Chapter 2 Controller Description

2.1 Controller parameters

   Main technical parameters of MH-32TK internal selection controller:

1. Input voltage: DC9 ~ 30V

2. Working current: <800mA

3. Operating environment temperature: -40 ℃ ~ + 70 ℃

4. Relative humidity of use environment: 20% ~ 90% non-condensing

5. Swipe operation time: <200 ms

6. Card reader cable length: 12 meters

7. Swipe record storage: 20,000 cycles

8. Number of manageable elevator cards: 60,000

9. Blacklist: 10,000

10. Elevator No .: 1 ~ 255 freely set

11. Mean time between failures:> 30000 hours

   2.2 Interface description

   Control board physical map:

   Interface Description:

J1

port

Features

Note

V +

Power +

DC 9-30V power input

GND

power supply-

Power ground

P4R +

485A

Computer network 485 signal +

P4R-

485B

Computer network 485 signal-

GND

Ground

Power ground

   J2

port

Features

Note

L4R-

485B

Building intercom linkage signal B

L4R +

485A

Building intercom linkage signal A

GND

Signal ground

Building Intercom Link Signal Ground

V +

Power Output

Card reader power output

GND

Power ground

Reader ground

D0

Data 0

Reader data DATA0

D1

Data 1

Reader data DATA1

GND

Ground

Emergency button switch ground

HF

restore

Emergency button switch input

The circuit switch, when it is turned to the left end (ON end), the control circuit is enabled and the IC card management function is enabled; when it is turned to (OFF end), the IC card management circuit is closed and the IC card management function is exited. Floor. When the IC management function fails, turn the switch to OFF to ensure the normal use of the elevator.

6.Layer selection control output interface JP **

A. If it is an ordinary elevator (supports 64-story control):

JP1 is connected to the bottom layer selection button, and then upwards ..., it can be connected to JP64.

B. The output status of each layer selection control is indicated by an indicator light. When the light is on, there is an output. The LD ** indicator corresponds to the output of KEY **.

Note: 1. JP1 here does not necessarily refer to the first floor, but refers to the bottom floor of the elevator to be controlled. For example, if the elevator has a basement level 1, JP1 controls the basement level here, and so on.

2. The range of “**” here is: 1 ~ 64. The “**” appearing later in this manual also has this meaning and will not be stated separately.

7. Elevator number setting dial switch S1

Through dial setting, the elevator number can be set to one of 1 ~ 255. For the setting method of elevator number, please refer to Appendix III.

   2.2 Eight-digit DIP switch S1 setting instructions

Set the controller number to one of 1 to 255 through the dial setting. The controller number must be unique. For the setting method of the elevator number, please refer to Appendix III of the manual.

9.Controller output indicator

When the control panel switch is in the ON state, the status of the LD ** indicator corresponds to the output status of the JP ** floor control output interface. The light indicates that the corresponding floor control has an output. At this time, you can choose the floor to take the elevator.

   Chapter III Installation Instructions

3.1 Controller wiring diagram

Note: 1), manual switch and fire switch are optional functions, choose whether to install as appropriate.

2) The "1" line of the button wiring is an automatic layer selection line. If the automatic layer selection is not used, it can be omitted.

), The system power supply can borrow the DC power supply in the elevator control panel box, the voltage range needs to meet DC9 ~ DC30.

3.2 Controller installation

3.2.1, Installation of MH-32TK internal controller

Solution A. If it is a retrofit of an already installed elevator, considering that no installation holes are reserved, in order to facilitate installation, four strong magnetic sheets have been installed on the back of the controller substrate, which can be adsorbed on the metal inner wall of the elevator car control panel Before cleaning, wipe off the dust in the adsorption area.

Solution B. If it is a new ladder that has not been shipped from the factory, you can reserve 4 circuit board mounting holes in the appropriate position in the control panel box, remove the insulating substrate on the back of the controller, and install the circuit board through insulating posts. For the mounting hole reservation method, see Icon:

3.2.3, card reader (reading head) installation method

The installation position can be selected on the control panel in the elevator car or on the inner wall of the car, the specific installation method is based on the actual card reader model.

3.3 Card Issuer and Computer Connection

Connection between card issuer and computer

The USB interface of the card issuer's communication cable is directly connected to the USB port of the computer, and the USB connector at the other end can be connected to the card issuer without driver.

   Chapter 4 Debugging and Running

4.1 Preparation before power on

1. Before powering on the circuit board, confirm whether the input voltage is within the normal range. The allowable operating voltage of the circuit board is: DC 9-30 volts

2. Check whether the circuit board is installed with reliable insulation and exclude any metal body overlapping it.

3.Check if the card reader is connected

4. Check whether the wiring of each terminal is correct

5. After confirming the above, connect the power supply to the power port on the circuit board. Do not connect it in the wrong position, causing the board to be damaged.

4.2 Check after power on

1. After the system is powered on, the indicator LED2 on the control board is on, indicating that the power is normal.

2. Turn the switch to the right. At this time, the working state is: Exit the IC card management mode. At this time, each floor should be free to choose the floor. If there is a floor that cannot be selected, please confirm that the wiring to the button is correct.

3. Turn the switch to the left end (ON end), then: enter the IC card management state.

4. Turn the switch to the left end (ON end), enable the IC card management circuit, close the fire switch, and select the layer freely. If the layer cannot be selected, please confirm that the wiring to the button is correct.

4.3 Controller configuration

1. Add the elevator information in the software of the elevator IC card management center. The elevator number should be the same as the elevator number set by the DIP switch S2 (check the corresponding elevator number in Appendix III). Add the elevator based on the actual information of the elevator. .

2. In the "controller settings" interface of the software, place the management card on the card issuer. Set the controller time, read and write sectors, read and write passwords, and so on, and then swipe the card on the card reader of the control board to adjust the controller time to the current time (note: the computer time must be accurate) The buzzer beeps four times: Drip-Drip-Drip-Drip indicates that the card swipe is set successfully.

4.4 Run the test

1. Observe whether the indicator of the card issuer is blinking. If it is blinking, refer to the following note to set it. If it is blinking, go down.

2. Make an elevator card, and check whether the corresponding floor output indicator is correct. If it is not correct, please confirm whether the elevator information set in the management center software is consistent with the controller setting. If there is no control output, please refer to Appendix I. The sound of the buzzer determines the cause.

3. Confirm whether the corresponding floor can be selected normally after swiping the card. If not, please confirm whether the floor output indicator is on. If it is on, please confirm whether the wiring to the button is correct and the controller floor output port to elevator selection. Whether the correspondence of the buttons is correct.

4. After the above tests are successful, the controller can work normally at this time.

   Chapter 5 Frequently Asked Questions

1. How to enable the IC card management function so that you can use the card to take the elevator?

Answer: Firstly, the switch of the low-level board needs to be at the "ON" side. After setting the management card to enable the elevator management to swipe the management card, the buzzer beeps four times and the LD1-LD32 indicator goes out, indicating that the controller enables the IC card management function.

2. How to exit the IC card management function and allow free selection of layers?

Answer: There are three ways to exit the IC card management function:

A. Turn the baseboard switch to the "OFF" side.

C, with manual switch input

D. Disable elevator management by software setting, swipe the management card, the buzzer beeps four times, and LD1-LD32 is on, indicating that the controller exits the IC card management function.

3. Why doesn't my swipe management card respond?

Answer: Confirm whether the card reader is connected correctly.

4.Why is there no response after swiping all the cards?

Answer: Please confirm whether it is authorized card issued by this system

5. I swiped the management card, enabled the IC card control, and the buzzer sounded four times, but why is it still in a non-IC card management state, but in a state where the layer can be selected freely?

Answer: Please confirm: 1), the bottom board switch should be on the "ON" side

2), no short-circuit signal input at the emergency recovery port

If any of the above conditions are not met, the IC management mode will be automatically exited.

6. Why do I want to use the second floor, but the floor control output indicator is LD3?

Answer: If the elevator has 1 underground floor, F1 indicates 1 underground floor, F3 indicates 2 floors above ground, which is normal. The indication status of other floors is also analogized in that order.

7.Why does the controller's layer selection control output not correspond to the floor usage rights of the elevator card I issued?

Answer: Please confirm a few points:

1) Whether the corresponding output status of the floor selection output indicator is correct should correspond to the card authorized floor output.

2) If the correspondence is correct, check whether the wiring sequence and corresponding relationship with the layer selection button are correct.

8.How to prohibit the use of the elevator for the owner's card?

A: The operation method is as follows: through the management center software, enter the blacklist management page, find the card number of the IC card held by the owner, and then put the management card> opt in to the blacklist (10 cards can be disabled at one time), Click the "Write Management Card" button on the back, or update the blacklist to the controller by networking. After holding the management card and swiping the card to the designated elevator, the IC card held by the owner will become invalid on the elevator. If you want to re-enable the owner ’s IC card that is prohibited from using the elevator, the operation method is the same

9.How to re-enable a disabled owner card?

A: The operation method is as follows: through the management center software, enter the blacklist management page, find the card number or room number of the IC card held by the owner, and then put the management card> select Cancel blacklist, click the "write" Enter the management card "button, or update the canceled blacklist to the controller via the network. After holding the management card to the designated elevator and swiping the card, holding the card to the designated elevator and swiping the card, the IC card held by the owner will become available again .

10.How to prohibit / enable all people in a room to use the elevator?

A: The operation method is as follows: through the management center software, enter the blacklist management page, find the house number of the owner, or the house number, and then put the management card> select to add the black list with the house number (can disable 10 cards at a time Card), click the "write management card" button on the back, or update the blacklist to the controller via the Internet. After holding the management card to the designated elevator and swiping the card, the IC card held by the owner of this room number will change on the elevator. Is invalid.

   Appendix 1 Detailed Explanation of Buzzer Beep

Swipe type

Sound type

Description

Owner card

silent

IC cards not issued by the management center software

This card does not have permission to use this controller

Soon

Swipe successfully, you can choose a layer

Two beeps:

Card used less than 10 times

Three sounds

Room number is disabled

Limited weekdays do not qualify

The date or number of rides does not match

Non-compliance with limited time

Privilege Card

silent

IC cards not issued by the management center software

Three sounds

The number of available times is 0, no more swipes

silent

This card does not have permission to operate this controller

Management Card

Four sounds

Resetting controller parameters succeeded

   Appendix III Setting Method of Elevator Number

The numerical value in the vertical column indicates the elevator number to be set, and the horizontal columns 1 to 8 represent the digits of the dial switch S2.

●: indicates that the digit is set to "ON"

Ladder number

8 -bit

7 -bit

6 digits

5 people

4 digits

3 digits

2 persons

1 person

Ladder number

8 -bit

7 -bit

6 digits

5 people

4 digits

3 digits

2 persons

1 person

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

twenty one

twenty two

twenty three

twenty four

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

129

130

131

132

133

134

135

136

137

138

139

140

141

142

143

144

145

146

147

148

149

150

151

152

153

154

155

156

157

158

159

160

161

162

163

164

165

166

167

168

169

170

171

172

173

174

175

176

177

178

179

180

181

182

183

184

185

186

187

188

189

190

191

192

193

194

195

196

197

198

199

200

201

202

203

204

205

206

207

208

209

210

211

212

213

214

215

216

217

218

219

220

221

222

223

224

225

226

227

228

229

230

231

232

233

234

235

236

237

238

239

240

241

242

243

244

245

246

247

248

249

250

251

252

253

254

255

Ladder number

8 -bit

7 -bit

6 digits

5 people

4 digits

3 digits

2 persons

1 person

Ladder number

8 -bit

7 -bit

6 digits

5 people

4 digits

3 digits

2 persons

1 person

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

twenty one

twenty two

twenty three

twenty four

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88